By McQuay

Show description

Read or Download AG31-004 - School HVAC Design Manual PDF

Best technique books

Woodworking Shopnotes 083 - Get organized

Each web page of ShopNotes journal will make you a greater woodworker, since you get extra woodworking plans, extra woodworking suggestions, extra woodworking jigs, and extra approximately woodworking instruments — and never a unmarried advert. For greater than 25 years, woodworkers have became to ShopNotes for the main exact woodworking plans and woodworking assistance to be had anyplace.

Fundamentals of Engineering Supplied-Reference Handbook

This can be the precise reference e-book you're given within the FE. Get to grasp it just like the again of your hand, and you will be that a lot forward in fixing difficulties quick, particularly difficulties no longer on your box of analysis so you might plug & chug should you recognize the place to discover the formulation. dwell with this booklet; consume, breathe, and sleep with this publication.

Springer Tracts in Advanced Robotics. Vol.38. Robotics and Cognitive Approaches to Spatial Mapping

This publication brings jointly the fields of robotic spatial mapping and cognitive spatial mapping, which percentage a few universal middle difficulties. One might quite anticipate a few cross–fertilisations of analysis among the 2 components to have happened, and this has occurred yet just recently. There are symptoms that either fields have matured and that efforts to cross–fertilise are taking place, however it is neither whole nor universal but.

Quality Engineering: Qualitat kommunikationstechnischer Systeme

Der Begriff der Qualität und der Gebrauchstauglichkeit hat eine herausragende Bedeutung in der Informations- und Kommunikationstechnik sowie der Informatik erlangt. In allen Phasen der Planung, Konzeption, Implementierung und Optimierung technischer Systeme und Dienste müssen Qualitätsaspekte berücksichtigtwerden, damit die Benutzer eine optimale Qualität und Gebrauchstauglichkeit erfahren können.

Extra resources for AG31-004 - School HVAC Design Manual

Example text

The system can transfer 385 mbh at -5°F. At 32°F ambient, the run around loop transfers 214 mbh. In most cases a three-way valve is required during cold weather as frost control. When the exhaust air temperature approaches 32°F, some fluid is bypassed around the outdoor air coil to avoid freezing the exhaust air coils. Another key design issue is the exhaust air coils will usually form condensate. They are “cooling coils” and as such require a drain pan piped to Application Guide AG 31-004 35 drain.

This is especially true for schools, which are built in residential neighborhoods. Radiated sound from the unit, particularly compressor sound, can be an issue at the property line. The designer should obtain the sound power levels and confirm the overall sound levels at the property line meet local codes. A method for this is described in McQuay SED 7512 and 9001. Vertical Self-Contained Systems Vertical self-contained units are institutional grade air conditioning units with water-cooled condensers.

Interoperability now allows easy integration. Factory supplied equipment controls offer: • A controller specifically designed and programmed for the particular piece of equipment and the application. • A full run factory test to demonstrate that the unit and controls are functioning properly. • Single source responsibility with equipment issues. • No conflicts about warranty responsibility. • Smoother commissioning. The technician commissioning the equipment can also commission the controls. The designer should familiarize themselves with controls capabilities and develop a controls strategy that will integrate new equipment and controls with the school with the school district’s existing infrastructure.